Description
Drager Aniline 0.5/a Detection Tubes
These Drager tubes measure aniline gas from 0.5 to 10 ppm. They work with the Drager Accuro pump for quick, on-site tests. Each pack has 10 tubes that last 2 years.
The tubes are great for checking spaces before entry and watching confined areas. They can also spot N,N’-Dimethylaniline.
You can reach tricky spots with special tools. Readings take between 10 seconds and 15 minutes, based on the tube type.
Key Facts:
- Measures: 0.5 to 10 ppm
- Pump strokes: 20
- Test time: About 4 minutes
- Colour change: Pale yellow to pale green
Use when:
- Temperature is 15 to 30 °C
- Humidity is 7 to 12 mg H2O / L
How it works:
C6H5NH2 + CrVI → CrIII + other products
Note: The tube may react to other chemicals like ethers and ketones.