Description
Drager Detection Tubes – Trichloroethane 50/d (Pack of 5)
Detect a variety of substances, including Bromochloromethane, Chloroethane, Methyl Chloroform, and Trichloroethane.
Product Details:
- Shelf Life: 2 years
- Pack Size: 5 tubes
- Tube Type: Trichloroethane 50/d
- Measurement Range: 0.5 to 5 mg/L
- Application: Measures 1,1,1-trichloroethane in water and wastewater
Specifications:
- Strokes Required: 5 + 3 desorption strokes in clean air
- Stroke Time: 40-70 s + 20-40 s
- Measurement Time: ~550 s + 90 s
- Sample Volume: 200 mL
- Colour Change: Grey to brown-red
- Temperature Range: 5°C to 35°C
- pH Measurement: Not required
Measurement Parameters:
Range (mg/L) | Deviation (%) | Temp (°C) | Parameters B, C |
---|---|---|---|
0.5 to 5 | 25 | 5 to 12 | 0.0059 – 50 |
25 | 13 to 25 | 0.0059 – 100 | |
30 | 26 to 33 | 0.0054 – 200 |
Calculation for 1,1,1-Trichloroethane Concentration:
Y[mg/L]=A⋅B⋅(X[ppm]+C)Y[mg/L] = A \cdot B \cdot (X[ppm] + C)Y[mg/L]=A⋅B⋅(X[ppm]+C)
Cross Sensitivity:
- Perchloroethylene, carbon tetrachloride, dichloromethane, and trichloroethylene show lower sensitivity.
- Petroleum hydrocarbons are not detected.